Bimba STP-10 Manuel d'utilisateur Page 24

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 39
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 23
STP-10 Hardware Manual
24
DRIVE
+
DC
Power
Supply
Proximity
Sensor
output
+
CW LIMIT+
CW LIMIT-
Connecting a Potentiometer to Analog Input 1
Analog Inputs
The STP drives feature two analog inputs. Each input can accept a signal range of 0
to 5 VDC, ±5 VDC, 0 to 10 VDC or ±10 VDC. The drive can be congured to operate
at a speed or position that is proportional to the analog signal.
A shielded cable is recommended for electrically noisy environments.
Use the IQ
®
Stepper software to set the signal range, offset, deadband and lter fre-
quency.
inside drive
AIN1
AIN2
GND
1
2
13
DB-25 Connector
Signal
Conditioning
Signal
Conditioning
1-10kW
pot
cw
ccw
DRIVE
GND
AIN
+5V OUT
18
1
13
AIN2
2
If the sensor output goes low at the limit, select the option “closed” (in the software). If the output is open, or high voltage, choose
“open”.
Other sensors have sourcing outputs. That means that current can ow out of the sensor output, but not into it. In that case, wire
the sensor this way: